Technical Specifications
   
- EN81-1 / 2 + A3 compliance with the standards.
- Available in a roped or hydraulic lifts.
- Must collect up to 24 stops, downward, upward and can run dual aspect double button.
- Call with the addition MLINT65 card entry and stop capacity can be increased.
- Password-protected programming, PUK code protection against unauthorized use.
- The last 16 faults; stop, direction, can be seen on the LCD screen along with the date and time information.
- Overload function
- Short-circuit protected outputs with adjustable display the desired code for each stop.
- Extra output of binary / Gray code or output can be selected as the gong. This output can feed an LCD screen on all outdoor installations.
- Full load function.
- Driver switch function.
- Orientation to stop previously set in case of fire.
- Adjustable parking stop and park travel time.
- Up-down counter for position information and bi-stable switch and encoder inputs and copy well.
- Be taken to the first stop of the cabin when the first energy upon request.
- Adjustable maintenance time, warning on the LCD screen when the maintenance period expired.
- LCD screen in standby mode after the last maintenance how the elevator of time (days, hours) to monitor its operation.
- Electronically phases, phase sequence and PTC (motor temperature) control, shown on the LCD screen of errors related to the controls, can be disabled with the choice of parameters, this function can adjust the phase level accuracy.
- Built-in automatic door card, automatic door adjustable time related to the work, each layer separately for the choice of the type of door and the floor on which the door is opened which will (be opened both at the same time) can be adjusted.
- MLSERI65 card full support without adding additional cards with double automatic doors.
- Depending on the direction of the arrow of the door opening signal selecting the operating mode.
- Display in the display will go to the first stop on each floor change the cabin selection.
- Limit switch cabinet or floor to be moved up to the level of choice in the revision.
- Hydraulic lifts, door open leveling can be done with the addition of MLKR1 card.
- Can not open the door early with the addition MLKR1 card.
- Lower and upper missing stop stop missing the duplex use to choose.
- Parameter support for recovery via UPS.
- Inputs and outputs necessary for recovery in the gearless synchronous motor system.
- Be able to expect automatic gates open on the floor.
- Speed Regulator contact or brake can cancel the feedback tracking